OK
12
12

Order Summary

3 Services

 1,234

View Cart
MORE
Store Timings
    PAY ONLINE
    CASH ON DELIVERY
    Note: This product is currently not available.
    The product name
    $ 150,000
    If you wish to buy more than one quantity of this product, please add the desired quantity in the next step.
    PROCEED TO PAYMENT
    After clicking the button, you will be redirected to a separate page.
    YOUR DETAILS
    ORDER DETAILS
    this is the product name that is to be bought
    $ 1200
    QTY
    Note: The delivery usually takes 2-5 days depending on availability and your location.
    bus bar
    Oh no! Nothing matches ‘’. Try something else?
    Technical Specification of EHV Substation Equipment and Materials for Substations and Overhead lines
    USD  3000
    USD 3000 (Save 0%)
    Not Available | Free Shipping
    Technical specification of the following EHV equipment and systems shall be prepared : - 400/220/132/33kV kV Circuit Breaker, Isolator, CT, PT, CVT & LA - 11/22/33kV Indoor switchgear - Auto Transformer, Power Transformer - Control & Relay panel - Substation Automation System - LV AC & DC distribution board - DC Battery and Battery Charger - MV, LV Control & Power Cable - Earthing & Lightning protection materials - Lighting fixtures - Steel structures, Clamps, Connectors, Insulators, Conductor, Al tube bus, cable glands, lugs, Hardware - Fiber optic communication system. - Power Line Carrier communication and EPAX
    Relay Setting Calculation & Coordination
    USD  3000
    USD 3000 (Save 0%)
    Not Available | Free Shipping
    We provide Relay Setting Calculations and Coordination charts for over current and earth fault protection of line feeders, transformers, reactors, capacitors in a high voltage substation. The calculations also include setting parameters for distance protection, differential protection, bus bar protection, over voltage and under voltage protections for large electrical HV and LV systems.
    SINGLE LINE DIAGRAM
    INR  0
    INR 0 (Save NaN%)
    Not Available | Free Shipping
    Single Line Diagram is one of the most important piece of drawing in a Project which describes the Power distribution philosophy, voltage step down or step up, equipment ratings, cable sizes, fault levels at various buses and protective relays provided at various voltage levels. Following type of drawings are generated for various projects : Key SLD for EHV AIS substation projects. Key SLD for EHV GIS substation projects. Key SLD for HV/MV Indoor substation projects. Key SLD of Thermal Power plants. Protection and metering SLD for EHV AIS substation projects. Protection and metering SLD for EHV GIS substation projects. Protection and metering SLD for HV/MV Indoor substation projects. Protection and metering SLD of Alternators. SLD of LV Switchgear panels. SLD of LV ACDB and DCDB panels. SLD of MV/LV MCC panels. Overall SLD of Lighting distribution in Large Plants. SLD of LV Bay Marshalling Kiosks (BMK) for EHV switch yards. SLD of P.F improvement Capacitor panels. SLD of Emergency power supply from DG sets.
    ELECTRICAL SYSTEM STUDY BY ETAP SOFTWARE
    USD  25000
    USD 25000 (Save 0%)
    Not Available | Free Shipping
    Electrical system studies by softwares are essential for initial planning for any project. Based on Clients requirements and data collected from site/other disciplines (like mechanical) a software model of the power distribution network can be created in ETAP software to do the following studies : Load flow study for Transformer sizing, Cable voltage drops and sizing, requirement of Capacitors for reactive power compensation. Load flow study also helps in deciding voltage levels at different buses of the substation. 3 phase and earth fault (SLG, LLG) level calculations at different node points of the power distribution system. Motor starting study for voltage drop during starting and normal running of the largest motor in a plant. Protection coordination study for proper relay coordination with upstream breaker. We have experienced manpower and softwares to execute these works. Kindly send us an enquiry to enable us to submit an offer matching with your requirements.
    33KV SWITCHYARD DESIGN (AIS/GIS)
    USD  30000
    USD 30000 (Save 0%)
    Not Available | Free Shipping
    We offer the following Design Engineering services for 132kV Switchyard projects : 1. Topographical contour survey 2. Geotechnical investigation 3. Soil resistivity measurement 4. Electrical SLD, protections, metering, controls and indications 5. Survey drawings, Topographical contour layout drawings 6. Overall site layout plan drawings 7. Switchyard layout plan & elevation drawings 8. Indoor and outdoor Cable trench layout drawings 9. Earthing calculation, layout and earthing detail drawings 10. DSLP calculation and layout drawings 11. Control schematics and terminal plan drawings of bay marshalling kiosks 12. Cable schedule and interconnection diagram for Power and control cables 13. Technical specification of all equipment and materials 14. Lighting calculations, SLD and layout drawings 15. Bill of materials for cables, cable trays, racks, earthing, lightning protection and lighting systems 16. Short circuit force calculation for strung bus and rigid tubular bus 17. Fault level calculation 18. CT & VT sizing calculations 19. Battery and battery charger sizing calculations 20. Vendor drawing review 21. Civil drawings and calculations for foundations, cable trenches, culverts, drains, control bldg., DG room, Store shed, Security room, Switchyard panel room (AC Kiosk), pump house, fire water reservoir 22. GS structure drawings for gantry towers, beams and equipment supports 23. SCADA architecture diagram, Input-Output list, BOM of SCADA system 24. Schematic diagrams, Layout drawings, specifications and BOM for Fire detection and alarm system 25. Schematic diagrams, Layout drawings, specifications and BOM for HVAC system We have experienced manpower and softwares to execute these works. Kindly send us an enquiry to enable us to submit an offer matching with your requirements.
    132KV SUBSTATION DESIGN
    USD  50000
    USD 50000 (Save 0%)
    Not Available | Free Shipping
    We offer the following Design Engineering services for 132kV Switchyard projects : 1. Topographical contour survey 2. Geotechnical investigation 3. Soil resistivity measurement 4. Electrical SLD, protections, metering, controls and indications 5. Survey drawings, Topographical contour layout drawings 6. Overall site layout plan drawings 7. Switchyard layout plan & elevation drawings 8. Indoor and outdoor Cable trench layout drawings 9. Earthing calculation, layout and earthing detail drawings 10. DSLP calculation and layout drawings 11. Control schematics and terminal plan drawings of bay marshalling kiosks 12. Cable schedule and interconnection diagram for Power and control cables 13. Technical specification of all equipment and materials 14. Lighting calculations, SLD and layout drawings 15. Bill of materials for cables, cable trays, racks, earthing, lightning protection and lighting systems 16. Short circuit force calculation for strung bus and rigid tubular bus 17. Fault level calculation 18. CT & VT sizing calculations 19. Battery and battery charger sizing calculations 20. Vendor drawing review 21. Civil drawings and calculations for foundations, cable trenches, culverts, drains, control bldg., DG room, Store shed, Security room, Switchyard panel room (AC Kiosk), pump house, fire water reservoir 22. GS structure drawings for gantry towers, beams and equipment supports 23. SCADA architecture diagram, Input-Output list, BOM of SCADA system 24. Schematic diagrams, Layout drawings, specifications and BOM for Fire detection and alarm system 25. Schematic diagrams, Layout drawings, specifications and BOM for HVAC system We have experienced manpower and softwares to execute these works. Kindly send us an enquiry to enable us to submit an offer matching with your requirements.
    220KV SUBSTATION DESIGN (AIS/GIS)
    USD  65000
    USD 65000 (Save 0%)
    Not Available | Free Shipping
    We offer the following Design and Engineering services for 220kV Switchyard/GIS substation projects : 1. Topographical contour survey 2. Geotechnical investigation 3. Soil resistivity measurement 4. Electrical SLD, protections, metering, controls and indications 5. Survey drawings, Topographical contour layout drawings 6. Overall site layout plan drawings 7. Switchyard layout plan & elevation drawings 8. Indoor and outdoor Cable trench layout drawings 9. Earthing calculation, layout and earthing details drawings 10. DSLP calculation and layout drawings 11. Control schematics and terminal plan drawings of Bay marshalling kiosks 12. Cable schedule and interconnection diagram for Power and control cables 13. Technical specification of all equipment and materials 14. Lighting calculations, SLD and layout drawings 15. Bill of materials for cables, cable trays, racks, earthing, lightning protection and lighting systems 16. Short circuit force calculation for strung bus and rigid tubular bus 17. Fault level calculation 18. CT & VT sizing calculations 19. Battery and battery charger sizing calculations 20. Vendor drawing review 21. Civil drawings and calculations for foundations, cable trenches, culverts, drains, control bldg., GIS building, DG room, Store shed, Security room, Switchyard panel room (AC Kiosk), pump house, fire water reservoir 22. GS structure drawings for gantry towers, beams and equipment supports 23. SCADA architecture diagram, Input-Output list, BOM of SCADA system 24. Schematic diagrams, specifications, layout drawings and BOM for Fire detection and alarm system 25. Schematic diagrams, specifications, layout drawings and BOM for HVAC system We have experienced manpower and softwares to execute these works. Kindly send us an enquiry to enable us to submit an offer matching with your requirements.
    SUBSTATION DESIGN
    USD  30000
    USD 30000 (Save 0%)
    Not Available | Free Shipping
    Substation design and engineering is our main focus area for more than 12 years. We have provided Design, Engineering and Consultancy services to many EPC companies like Alstom, Siemens, Sterling & Wilson, Mcnally Bharat etc. for their high voltage substation projects for Utilities and Large Industries. Some of the major substations designed by us are as follows : 1. 220/132/33kV outdoor AIS substation of WBSETCL at Howrah Foundry park (On behalf of Siemens Ltd.) 2. 400/220kV, 1x315MVA Transformer bay extension at Jeerat and Arambag substations of WBSETCL (On behalf of Siemens Ltd.) 3. 220/132/33kV outdoor AIS substation of JSEB at Chatra (On behalf of Flowmore Ltd.) 4. 132/33kV outdoor AIS substation of JSEB at Tamar (On behalf of Flowmore Ltd.) 5. 400/220/132kV outdoor AIS substation of APTRANSCO at Jammalamadugu (On behalf of Techno Electric, Kolkata) 6. 132/33kV Outdoor substation of WBSETCL at UAJNU and 1 no. 132kV Line bay extension at 8 nos substations (On behalf of Mcnally Bharat Engineering Co. Ltd.) 7. 132/33kV WUDIL AIS Substation of TCN in Nigeria (On behalf of Supreme & Co.Pvt. Ltd., Kolkata). 8. 132/33/6.6kV GIS substation and downstream ring main system for Construction power system of NMDC for 3 MTPY Integrated steel plant at Nagarnar, Chattisgarh. (On behalf of KEC, International, Gurgaon). 9. 132/33kV GIS MRSS of Tata Steel Ltd. at Noamundi, Jharkhand for Joda & Noamundi Mines expansion project (on behalf of Siemens Ltd). 10.1x400kV Bus reactor bay extension of PGCIL in Amritsar, Hissar, Nalagarh and Jalandhar on behalf of Sterling & Wilson Ltd. For details of many other current and completed projects please refer to our website www.satcon.in. Our design processes are fully computerised and designs are carried out as per relevant national/international standards and Customer's specifications. We being an ISO 9001 certified company, our work procedures are guided by the guidelines of the ISO standard procedures. Our main strengths are - Extensive domain knowledge, wide experience in Indian and International field, competitive price, fast delivery time, knowledgeable manpower, willing to work, willing to listen and learn.
    400KV SUBSTATION DESIGN (AIS/GIS)
    USD  75000
    USD 75000 (Save 0%)
    Not Available | Free Shipping
    We offer the following Design and Engineering services for Switchyard Substation projects upto 400kV : 1. Topographical contour survey 2. Geotechnical investigation 3. Soil resistivity measurement 4. Electrical SLD, protections, metering, controls and indications 5. Survey drawings, Topographical contour layout drawings 6. Overall site layout plan drawings 7. Switchyard layout plan & elevation drawings 8. Indoor and outdoor Cable trench layout drawings 9. Earthing calculation, layout and earthing details drawings 10. DSLP calculation and layout drawings 11. Control schematics and terminal plan drawings of Bay marshalling kiosks 12. Cable schedule and interconnection diagram for Power and control cables 13. Technical specification of all equipment and materials 14. Lighting calculations, SLD and layout drawings 15. Bill of materials for cables, cable trays, racks, earthing, lightning protection and lighting systems 16. Short circuit force calculation for strung bus and rigid tubular bus 17. Fault level calculation 18. CT & VT sizing calculations 19. Battery and battery charger sizing calculations 20. Vendor drawing review 21. Civil drawings and calculations for foundations, cable trenches, culverts, drains, control bldg., DG room, Store shed, Security room, Switchyard panel room (AC Kiosk), pump house, fire water reservoir 22. GS structure drawings for gantry towers, beams and equipment supports 23. SCADA architecture diagram, Input-Output list, BOM of SCADA system 24. Schematic diagrams, specifications and BOM for Fire detection and alarm system 25. Schematic diagrams, specifications, Layout drawings and BOM for HVAC system We have experienced manpower and softwares to execute these works. Kindly send us an enquiry to enable us to submit an offer matching with your requirements.